Compare / 1.4162 vs 1.4362
1.4162 vs 1.4362
EN 10088-2/-3/-4/-5 · Stainless steel
Lean duplex: twice the proof strength of 304 (450 MPa plate) with little nickel.
EN 10088-2/-3/-4/-5 · Stainless steel
Duplex 2304: fy 400 MPa plate, corrosion resistance similar to 316.
Mechanical
| Property | Condition | 1.4162 | 1.4362 | Difference |
|---|---|---|---|---|
| 0.2 % proof strength Rp0.2 | t = 6.4 mm · cold rolled strip | ≥ 530MPa1 | ≥ 450MPa1 | −15 % |
| t = 10 mm · hot rolled strip | ≥ 480MPa1 | ≥ 400MPa1 | −17 % | |
| t = 75 mm · hot rolled plate | ≥ 450MPa2 | ≥ 400MPa2 | −11 % | |
| t = 160 mm · bars, rods and sections | ≥ 450MPa1 | ≥ 400MPa1 | −11 % | |
| Tensile strength Rm | t = 6.4 mm · cold rolled strip | ≥ 700MPa1 | ≥ 650MPa1 | −7.1 % |
| t = 10 mm · hot rolled strip | ≥ 680MPa1 | ≥ 650MPa1 | −4.4 % | |
| t = 75 mm · hot rolled plate | ≥ 650MPa2 | ≥ 630MPa2 | −3.1 % | |
| t = 160 mm · bars, rods and sections | ≥ 650MPa1 | ≥ 600MPa1 | −7.7 % | |
| Elongation after fracture A | t = 75 mm · hot rolled plate | ≥ 30%1 | ≥ 25%1 | −17 % |
| Modulus of elasticity E | — | 200 000MPa1 | 200 000MPa1 | same |
| Shear modulus G | — | 76 900MPa1 | 76 900MPa1 | same |
| Poisson's ratio ν | — | 0.31 | 0.31 | same |
Design values
| Property | Condition | 1.4162 | 1.4362 | Difference |
|---|---|---|---|---|
| Partial factor for the material γM | cross-sections, γM0 | 1.11 | 1.11 | same |
| member instability, γM1 | 1.11 | 1.11 | same | |
| tension to fracture, bolts, welds, γM2 | 1.251 | 1.251 | same |
Physical
| Property | Condition | 1.4162 | 1.4362 | Difference |
|---|---|---|---|---|
| Density ρ | — | 7 700kg/m³1 | 7 800kg/m³1 | +1.3 % |
Thermal
| Property | Condition | 1.4162 | 1.4362 | Difference |
|---|---|---|---|---|
| Coefficient of thermal expansion α | 20–100 °C | 13×10⁻⁶ /K1 | 13×10⁻⁶ /K1 | same |
| Specific heat capacity cp | at +20 °C | 500J/(kg·K)1 | 500J/(kg·K)1 | same |
| Thermal conductivity λ | at +20 °C | 15W/(m·K)1 | 15W/(m·K)1 | same |
Chemical and durability
| Property | Condition | 1.4162 | 1.4362 | Difference |
|---|---|---|---|---|
| Corrosion resistance class CRC | — | III1 | III1 |
Fire
| Property | Condition | 1.4162 | 1.4362 | Difference |
|---|---|---|---|---|
| 0.2 % proof strength reduction factor in fire kp0.2,θ | at +20 °C | 11 | 11 | same |
| at +100 °C | 0.821 | 0.831 | +1.2 % | |
| at +200 °C | 0.71 | 0.751 | +7.1 % | |
| at +300 °C | 0.651 | 0.691 | +6.2 % | |
| at +400 °C | 0.61 | 0.581 | −3.3 % | |
| at +500 °C | 0.531 | 0.431 | −19 % | |
| at +600 °C | 0.421 | 0.271 | −36 % | |
| at +700 °C | 0.271 | 0.141 | −48 % | |
| at +800 °C | 0.151 | 0.071 | −53 % | |
| at +900 °C | 0.071 | 0.041 | −43 % | |
| at +1000 °C | 0.011 | — | ||
| Elastic modulus reduction factor kE,θ | at +20 °C | 11 | 11 | same |
| at +100 °C | 0.961 | 0.961 | same | |
| at +200 °C | 0.921 | 0.921 | same | |
| at +300 °C | 0.881 | 0.881 | same | |
| at +400 °C | 0.841 | 0.841 | same | |
| at +500 °C | 0.81 | 0.81 | same | |
| at +600 °C | 0.761 | 0.761 | same | |
| at +700 °C | 0.711 | 0.711 | same | |
| at +800 °C | 0.631 | 0.631 | same | |
| at +900 °C | 0.451 | 0.451 | same | |
| at +1000 °C | 0.21 | — | ||
| Ultimate strength reduction factor ku,θ | at +20 °C | 11 | 11 | same |
| at +100 °C | 0.961 | 0.941 | −2.1 % | |
| at +200 °C | 0.911 | 0.871 | −4.4 % | |
| at +300 °C | 0.881 | 0.791 | −10 % | |
| at +400 °C | 0.821 | 0.71 | −15 % | |
| at +500 °C | 0.711 | 0.591 | −17 % | |
| at +600 °C | 0.561 | 0.471 | −16 % | |
| at +700 °C | 0.381 | 0.331 | −13 % | |
| at +800 °C | 0.221 | 0.21 | −9.1 % | |
| at +900 °C | 0.141 | 0.091 | −36 % | |
| at +1000 °C | 0.061 | — |
Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are 1.4362 relative to 1.4162; for ranges the lower bound is compared.