EuropeEN 485-2· Europe

5083-H22

Quarter-hard 5083: 215 MPa proof, 305 MPa tensile up to 40 mm; HAZ falls to 155/275 MPa.

Eurocode 9 gives H12 the same tensile with a higher proof (250 MPa) and 3 % elongation.

0.2 % proof strength Rp0.2
≥ 215MPa
From the standard≤ 40 mm
Tensile strength Rm
≥ 305MPa
From the standard≤ 40 mm
Elongation after fracture A
≥ 5%
From the standard≤ 40 mm · A50 or A as in Table 3.2a
Characteristic proof strength fo
215MPa
From the standard≤ 40 mm
Characteristic ultimate strength fu
305MPa
From the standard≤ 40 mm
HAZ proof strength fo,haz
155MPa
From the standard≤ 40 mm
HAZ ultimate strength fu,haz
275MPa
From the standard≤ 40 mm

All values

Mechanical

Strength

0.2 % proof strength Rp0.2

ConditionValueEvidence
≥ 215MPaFrom the standard

Tensile strength Rm

ConditionValueEvidence
≥ 305MPaFrom the standard

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 5%From the standard

Design values

Characteristic proof strength fo

ConditionValueEvidence
215MPaFrom the standard

Characteristic ultimate strength fu

ConditionValueEvidence
305MPaFrom the standard

HAZ proof strength fo,haz

ConditionValueEvidence
155MPaFrom the standard

HAZ ultimate strength fu,haz

ConditionValueEvidence
275MPaFrom the standard

Sources here are public pages that reproduce EN 485-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.