EuropeEN 485-2· Europe

5083-H24

Half-hard 5083: 250 MPa proof, 340 MPa tensile up to 25 mm, buckling class A.

0.2 % proof strength Rp0.2
≥ 250MPa
From the standard≤ 25 mm
Tensile strength Rm
≥ 340MPa
From the standard≤ 25 mm
Elongation after fracture A
≥ 4%
From the standard≤ 25 mm · A50 or A as in Table 3.2a
Characteristic proof strength fo
250MPa
From the standard≤ 25 mm
Characteristic ultimate strength fu
340MPa
From the standard≤ 25 mm
HAZ proof strength fo,haz
155MPa
From the standard≤ 25 mm
HAZ ultimate strength fu,haz
275MPa
From the standard≤ 25 mm

All values

Mechanical

Strength

0.2 % proof strength Rp0.2

ConditionValueEvidence
≥ 250MPaFrom the standard

Tensile strength Rm

ConditionValueEvidence
≥ 340MPaFrom the standard

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 4%From the standard

Design values

Characteristic proof strength fo

ConditionValueEvidence
250MPaFrom the standard

Characteristic ultimate strength fu

ConditionValueEvidence
340MPaFrom the standard

HAZ proof strength fo,haz

ConditionValueEvidence
155MPaFrom the standard

HAZ ultimate strength fu,haz

ConditionValueEvidence
275MPaFrom the standard

Sources here are public pages that reproduce EN 485-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.