5083-H24
Half-hard 5083: 250 MPa proof, 340 MPa tensile up to 25 mm, buckling class A.
- 0.2 % proof strength Rp0.2
- ≥ 250MPaFrom the standard≤ 25 mm
- Tensile strength Rm
- ≥ 340MPaFrom the standard≤ 25 mm
- Elongation after fracture A
- ≥ 4%From the standard≤ 25 mm · A50 or A as in Table 3.2a
- Characteristic proof strength fo
- 250MPaFrom the standard≤ 25 mm
- Characteristic ultimate strength fu
- 340MPaFrom the standard≤ 25 mm
- HAZ proof strength fo,haz
- 155MPaFrom the standard≤ 25 mm
- HAZ ultimate strength fu,haz
- 275MPaFrom the standard≤ 25 mm
All values
- Identity and composition not yet
- Mechanical 3
- Design values 4
- Physical not yet
- Thermal not yet
- Fire not yet
- Chemical and durability not yet
Mechanical
Strength
0.2 % proof strength Rp0.2
Minimum 0.2 % proof strength guaranteed by the product standard.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 250MPa | From the standard |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 340MPa | From the standard |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 4% | From the standard |
Design values
Characteristic proof strength fo
fo for design to Eurocode 9 (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 250MPa | From the standard |
Characteristic ultimate strength fu
fu for design to Eurocode 9.
| Condition | Value | Evidence |
|---|---|---|
| 340MPa | From the standard |
HAZ proof strength fo,haz
0.2 % proof strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 155MPa | From the standard |
HAZ ultimate strength fu,haz
Ultimate strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 275MPa | From the standard |
Sources here are public pages that reproduce EN 485-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.