EuropeEN 485-2· Europe

5083-O/H111

The strongest common non-heat-treatable plate: 125 MPa proof, 275 MPa tensile up to 50 mm, unaffected by welding.

Shipbuilding, pressure vessels, cryogenic tanks. For hulls, the H116 and H321 tempers are tested against exfoliation corrosion.

0.2 % proof strength Rp0.2
≥ 125MPa
From the standard≤ 50 mm
Tensile strength Rm
≥ 275MPa
From the standard≤ 50 mm
Elongation after fracture A
≥ 11%
From the standard≤ 50 mm · A50 or A as in Table 3.2a
Characteristic proof strength fo
125MPa
From the standard≤ 50 mm
Characteristic ultimate strength fu
275MPa
From the standard≤ 50 mm
HAZ proof strength fo,haz
125MPa
From the standard≤ 50 mm
HAZ ultimate strength fu,haz
275MPa
From the standard≤ 50 mm

All values

Mechanical

Strength

0.2 % proof strength Rp0.2

ConditionValueEvidence
≥ 125MPaFrom the standard1
≥ 115MPaFrom the standard

Tensile strength Rm

ConditionValueEvidence
≥ 275MPaFrom the standard
≥ 270MPaFrom the standard

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 11%From the standard
≥ 14%From the standard

Design values

Characteristic proof strength fo

ConditionValueEvidence
125MPaFrom the standard
115MPaFrom the standard

Characteristic ultimate strength fu

ConditionValueEvidence
275MPaFrom the standard
270MPaFrom the standard

HAZ proof strength fo,haz

ConditionValueEvidence
125MPaFrom the standard
115MPaFrom the standard

HAZ ultimate strength fu,haz

ConditionValueEvidence
275MPaFrom the standard
270MPaFrom the standard

Sources here are public pages that reproduce EN 485-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.