6060-T6
Solution-treated and aged 6060: 150 MPa proof and 190 MPa tensile up to 5 mm, 140/170 MPa up to 25 mm.
The most common alloy for window, façade and general profiles. Eurocode 9 uses one value for design, fo = 140 MPa and fu = 170 MPa up to 15 mm — the thicker-wall minimums — because it must hold for every product form.
- 0.2 % proof strength Rp0.2
- ≥ 140MPaCorroborated5–25 mm
- Tensile strength Rm
- ≥ 170MPaCorroborated5–25 mm
- Elongation after fracture A
- ≥ 8%Corroborated5–25 mm · A (L₀ = 5.65√S₀)
All values
- Identity and composition 8
- Mechanical 7
- Design values 4
- Physical 1
- Thermal not yet
- Fire not yet
- Chemical and durability not yet
Mechanical
Elastic
Modulus of elasticity E
Young's modulus for design.
| Condition | Value | Evidence |
|---|---|---|
| 70 000MPa | Confirmed |
Strength
0.2 % proof strength Rp0.2
Minimum 0.2 % proof strength guaranteed by the product standard.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 150MPa | Single source1 | |
| ≥ 140MPa | Corroborated |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 190MPa | Single source1 | |
| ≥ 170MPa | Corroborated |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 8% | Single source | |
| ≥ 8% | Corroborated |
Design values
Characteristic proof strength fo
fo for design to Eurocode 9 (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 140MPa | From the standard |
Characteristic ultimate strength fu
fu for design to Eurocode 9.
| Condition | Value | Evidence |
|---|---|---|
| 170MPa | From the standard |
HAZ proof strength fo,haz
0.2 % proof strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 60MPa | From the standard |
HAZ ultimate strength fu,haz
Ultimate strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 100MPa | From the standard |
Physical
Density ρ
Mass per unit volume.
| Condition | Value | Evidence |
|---|---|---|
| 2 700kg/m³ | Single source1 |
Chemical composition
Show on the periodic tableEN AW-6060, % by mass (EN 573-3, per Hydro)
| Element | Applies to | Max % | Evidence |
|---|---|---|---|
| Si | all thicknesses | 0.60 | Single source |
| Fe | all thicknesses | 0.30 | Single source |
| Cu | all thicknesses | 0.10 | Single source |
| Mn | all thicknesses | 0.10 | Single source |
| Mg | all thicknesses | 0.60 | Single source |
| Cr | all thicknesses | 0.050 | Single source |
| Zn | all thicknesses | 0.15 | Single source |
| Ti | all thicknesses | 0.10 | Single source |
Sources here are public pages that reproduce EN 755-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.