6060-T66
6060 with controlled composition for higher strength: 160 MPa proof and 215 MPa tensile up to 5 mm.
T66 is a European temper (EN 515): higher properties than T6, reached with a little more Mg and Si. That is also why its HAZ values are slightly higher than T6's. Eurocode 9 still uses the 3 mm band of the older EN 755-2.
- 0.2 % proof strength Rp0.2
- ≥ 150MPaCorroborated5–25 mm
- Tensile strength Rm
- ≥ 195MPaCorroborated5–25 mm
- Elongation after fracture A
- ≥ 8%Corroborated5–25 mm · A (L₀ = 5.65√S₀)
- Characteristic proof strength fo
- 150MPaFrom the standard3–25 mm
- Characteristic ultimate strength fu
- 195MPaFrom the standard3–25 mm
- HAZ proof strength fo,haz
- 65MPaFrom the standard3–25 mm
- HAZ ultimate strength fu,haz
- 110MPaFrom the standard3–25 mm
All values
- Identity and composition 8
- Mechanical 6
- Design values 8
- Physical not yet
- Thermal not yet
- Fire not yet
- Chemical and durability not yet
Mechanical
Strength
0.2 % proof strength Rp0.2
Minimum 0.2 % proof strength guaranteed by the product standard.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 160MPa | Single source1 | |
| ≥ 150MPa | Corroborated |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 215MPa | Single source1 | |
| ≥ 195MPa | Corroborated |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 8% | Single source | |
| ≥ 8% | Corroborated |
Design values
Characteristic proof strength fo
fo for design to Eurocode 9 (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 160MPa | From the standard | |
| 150MPa | From the standard |
Characteristic ultimate strength fu
fu for design to Eurocode 9.
| Condition | Value | Evidence |
|---|---|---|
| 215MPa | From the standard | |
| 195MPa | From the standard |
HAZ proof strength fo,haz
0.2 % proof strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 65MPa | From the standard | |
| 65MPa | From the standard |
HAZ ultimate strength fu,haz
Ultimate strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 110MPa | From the standard | |
| 110MPa | From the standard |
Chemical composition
Show on the periodic tableEN AW-6060, % by mass (EN 573-3, per Hydro)
| Element | Applies to | Max % | Evidence |
|---|---|---|---|
| Si | all thicknesses | 0.60 | Single source |
| Fe | all thicknesses | 0.30 | Single source |
| Cu | all thicknesses | 0.10 | Single source |
| Mn | all thicknesses | 0.10 | Single source |
| Mg | all thicknesses | 0.60 | Single source |
| Cr | all thicknesses | 0.050 | Single source |
| Zn | all thicknesses | 0.15 | Single source |
| Ti | all thicknesses | 0.10 | Single source |
Sources here are public pages that reproduce EN 755-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.