EuropeEN 755-2· Europe

6063-T5

Press-quenched 6063 for architectural profiles: 130 MPa proof and 175 MPa tensile up to 10 mm.

0.2 % proof strength Rp0.2
≥ 110MPa
Single source10–25 mm
Tensile strength Rm
≥ 160MPa
Single source10–25 mm
Elongation after fracture A
≥ 7%
Single source10–25 mm · A (L₀ = 5.65√S₀)
Characteristic proof strength fo
110MPa
From the standard3–25 mm
Characteristic ultimate strength fu
160MPa
From the standard3–25 mm
HAZ proof strength fo,haz
60MPa
From the standard3–25 mm
HAZ ultimate strength fu,haz
100MPa
From the standard3–25 mm

All values

Mechanical

Strength

0.2 % proof strength Rp0.2

ConditionValueEvidence
≥ 130MPaSingle source
≥ 110MPaSingle source

Tensile strength Rm

ConditionValueEvidence
≥ 175MPaSingle source
≥ 160MPaSingle source

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 8%Single source
≥ 7%Single source

Design values

Characteristic proof strength fo

ConditionValueEvidence
130MPaFrom the standard
110MPaFrom the standard

Characteristic ultimate strength fu

ConditionValueEvidence
175MPaFrom the standard
160MPaFrom the standard

HAZ proof strength fo,haz

ConditionValueEvidence
60MPaFrom the standard
60MPaFrom the standard

HAZ ultimate strength fu,haz

ConditionValueEvidence
100MPaFrom the standard
100MPaFrom the standard

Chemical composition

Show on the periodic table

EN AW-6063, % by mass (EN 573-3, per Hydro)

ElementApplies toMax %Evidence
Siall thicknesses0.60Single source
Feall thicknesses0.35Single source
Cuall thicknesses0.10Single source
Mnall thicknesses0.10Single source
Mgall thicknesses0.90Single source
Crall thicknesses0.10Single source
Znall thicknesses0.10Single source
Tiall thicknesses0.10Single source

Sources here are public pages that reproduce EN 755-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.