6082-T5
Press-quenched 6082 for thin profiles: 230 MPa proof, 270 MPa tensile up to 5 mm.
No values beyond 5 mm for 6082-T5 in this data.
All values
- Identity and composition 8
- Mechanical 3
- Design values 4
- Physical not yet
- Thermal not yet
- Fire not yet
- Chemical and durability not yet
Mechanical
Strength
0.2 % proof strength Rp0.2
Minimum 0.2 % proof strength guaranteed by the product standard.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 230MPa | Confirmed |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 270MPa | Confirmed |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 8% | Confirmed |
Design values
Characteristic proof strength fo
fo for design to Eurocode 9 (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 230MPa | From the standard |
Characteristic ultimate strength fu
fu for design to Eurocode 9.
| Condition | Value | Evidence |
|---|---|---|
| 270MPa | From the standard |
HAZ proof strength fo,haz
0.2 % proof strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 125MPa | From the standard |
HAZ ultimate strength fu,haz
Ultimate strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 185MPa | From the standard |
Chemical composition
Show on the periodic tableEN AW-6082, % by mass (EN 573-3, per Hydro)
| Element | Applies to | Max % | Evidence |
|---|---|---|---|
| Si | all thicknesses | 1.30 | Single source |
| Fe | all thicknesses | 0.50 | Single source |
| Cu | all thicknesses | 0.10 | Single source |
| Mn | all thicknesses | 1.00 | Single source |
| Mg | all thicknesses | 1.20 | Single source |
| Cr | all thicknesses | 0.25 | Single source |
| Zn | all thicknesses | 0.20 | Single source |
| Ti | all thicknesses | 0.10 | Single source |
Sources here are public pages that reproduce EN 755-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.