6082-T6/T651 plate
Heat-treatable structural plate: 260 MPa proof up to 6 mm, 255 up to 12.5 mm, 240 MPa to 100 mm.
- 0.2 % proof strength Rp0.2
- ≥ 240MPaFrom the standard12.5–100 mm
- Tensile strength Rm
- ≥ 295MPaFrom the standard12.5–100 mm
- Elongation after fracture A
- ≥ 7%From the standard12.5–100 mm · A50 or A as in Table 3.2a
- Characteristic proof strength fo
- 240MPaFrom the standard12.5–100 mm
- Characteristic ultimate strength fu
- 295MPaFrom the standard12.5–100 mm
- HAZ proof strength fo,haz
- 125MPaFrom the standard12.5–100 mm
- HAZ ultimate strength fu,haz
- 185MPaFrom the standard12.5–100 mm
All values
- Identity and composition 8
- Mechanical 11
- Design values 12
- Physical not yet
- Thermal not yet
- Fire not yet
- Chemical and durability not yet
Mechanical
Strength
0.2 % proof strength Rp0.2
Minimum 0.2 % proof strength guaranteed by the product standard.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 260MPa | From the standard | |
| ≥ 255MPa | From the standard | |
| ≥ 240MPa | From the standard | |
| ≥ 240MPa | Trade sources only |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 310MPa | From the standard | |
| ≥ 300MPa | From the standard | |
| ≥ 295MPa | From the standard | |
| ≥ 275MPa | Trade sources only |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 6% | From the standard | |
| ≥ 9% | From the standard | |
| ≥ 7% | From the standard |
Design values
Characteristic proof strength fo
fo for design to Eurocode 9 (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 260MPa | From the standard | |
| 255MPa | From the standard | |
| 240MPa | From the standard |
Characteristic ultimate strength fu
fu for design to Eurocode 9.
| Condition | Value | Evidence |
|---|---|---|
| 310MPa | From the standard | |
| 300MPa | From the standard | |
| 295MPa | From the standard |
HAZ proof strength fo,haz
0.2 % proof strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 125MPa | From the standard | |
| 125MPa | From the standard | |
| 125MPa | From the standard |
HAZ ultimate strength fu,haz
Ultimate strength in the heat-affected zone of a weld (Eurocode 9).
| Condition | Value | Evidence |
|---|---|---|
| 185MPa | From the standard | |
| 185MPa | From the standard | |
| 185MPa | From the standard |
Chemical composition
Show on the periodic tableEN AW-6082, % by mass (EN 573-3, per Hydro)
| Element | Applies to | Max % | Evidence |
|---|---|---|---|
| Si | all thicknesses | 1.30 | Single source |
| Fe | all thicknesses | 0.50 | Single source |
| Cu | all thicknesses | 0.10 | Single source |
| Mn | all thicknesses | 1.00 | Single source |
| Mg | all thicknesses | 1.20 | Single source |
| Cr | all thicknesses | 0.25 | Single source |
| Zn | all thicknesses | 0.20 | Single source |
| Ti | all thicknesses | 0.10 | Single source |
Not yet verified for this grade
- Plate over 100 mm from a mill's datasheet (Eurocode 9 stops at 100 mm)
Missing on purpose: a value appears here only once a public source states it.
Sources here are public pages that reproduce EN 485-2. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.