Matipedia
InternationalISO 898-1· International

Property class 8.8

The everyday structural bolt: 800 MPa tensile, 640 MPa yield (nominal). Minimums rise above 16 mm diameter.

All values

Strength

Yield strength ReH

ConditionValueEvidence
≥ 640MPaSingle source
≥ 660MPaSingle source

Tensile strength Rm

ConditionValueEvidence
≥ 800MPaSingle source
≥ 830MPaSingle source

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 12%Corroborated

Design values (Eurocode)

Design yield strength fy

ConditionValueEvidence
640MPaSingle source

Design ultimate strength fu

ConditionValueEvidence
800MPaSingle source

Property class 8.8 in other standards

Full comparison

“Equivalent” tables online usually match grades by name. This one compares the values each standard actually guarantees, so a 30 MPa gap in yield is visible before it is in your calculation.

GradeStandardMin. yield at 10 mmTensile at 10 mmMatchWhat differs
Property class 8.8InternationalISO 898-1≥ 640MPa1≥ 800MPa1—Reference grade.
F3125 Grade A325United StatesASTM F3125/F3125M≥ 634MPa2≥ 827MPa2Close match120 ksi (827 MPa) tensile and 92 ksi (634 MPa) yield, close to 8.8 above 16 mm; inch threads.

Sources here are public pages that reproduce ISO 898-1. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence.