Matipedia
EuropeEN 10346:2015· Europe

S550GD

Full-hard coated sheet: 550 MPa yield, 560 MPa tensile, no elongation requirement.

Cold-reduced without recovery annealing: very strong but with little ductility, for roofing and decking profiles. Design codes limit how much of that strength may be used.

All values

Strength

Yield strength ReH

ConditionValueEvidence
≥ 550MPaSingle source

Tensile strength Rm

ConditionValueEvidence
≥ 560MPaSingle source

S550GD in other standards

Full comparison

“Equivalent” tables online usually match grades by name. This one compares the values each standard actually guarantees, so a 30 MPa gap in yield is visible before it is in your calculation.

GradeStandardMin. yield at 10 mmTensile at 10 mmMatchWhat differs
S550GDEuropeEN 10346:2015≥ 550MPa1≥ 560MPa1—Reference grade.
G550Australia & New ZealandAS 1397≥ 550MPa1≥ 550MPa1Close matchSame 550 MPa yield; tensile 550 MPa (vs 560). AS/NZS 4600 reduces G550 below 0.9 mm to 75 % of its strength in design.
A653 SS Grade 80United StatesASTM A653/A653M≥ 550MPa1≥ 570MPa1Close match550 MPa (80 ksi) yield, 570 MPa (82 ksi) tensile, no elongation requirement.

Sources here are public pages that reproduce EN 10346:2015. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence.