EuropeEN 338:2016· Europe

C40

Softwood strength class: bending 40 MPa, E0,mean 14 000 MPa, ρk 400 kg/m³.

All values

Mechanical

Elastic

Modulus of elasticity parallel to grain E0,mean

ConditionValueEvidence
14 000MPaCorroborated

Shear modulus Gmean

ConditionValueEvidence
880MPaCorroborated

Modulus of elasticity, 5th percentile E0,05

ConditionValueEvidence
9 400MPacharacteristicCorroborated

Modulus of elasticity perpendicular to grain E90,mean

ConditionValueEvidence
470MPaCorroborated

Strength

Bending strength fm,k

ConditionValueEvidence
40MPacharacteristicCorroborated

Tension parallel to grain ft,0,k

ConditionValueEvidence
26MPacharacteristicCorroborated

Compression parallel to grain fc,0,k

ConditionValueEvidence
27MPacharacteristicCorroborated

Shear strength fv,k

ConditionValueEvidence
4MPacharacteristicCorroborated

Tension perpendicular to grain ft,90,k

ConditionValueEvidence
0.4MPacharacteristicCorroborated

Compression perpendicular to grain fc,90,k

ConditionValueEvidence
2.8MPacharacteristicCorroborated

Design values

Modification factor for load duration and moisture kmod

ConditionValueEvidence
0.6Single source
0.5Single source
0.7Single source
0.55Single source
0.8Single source
0.65Single source
0.9Single source
0.7Single source
1.1Single source
0.9Single source

Deformation factor (creep) kdef

ConditionValueEvidence
0.6Single source
0.8Single source
2Single source

Partial factor for the material γM

ConditionValueEvidence
1.3Single source

Physical

Characteristic density ρk

ConditionValueEvidence
400kg/m³characteristicCorroborated

Mean density ρmean

ConditionValueEvidence
480kg/m³Corroborated

Fire

One-dimensional charring rate β0

ConditionValueEvidence
0.65mm/minSingle source

Notional charring rate βn

ConditionValueEvidence
0.8mm/minSingle source

Sources here are public pages that reproduce EN 338:2016. For design and acceptance, the standard edition named in your specification and the CE marking and Declaration of Performance of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.