EuropeEN 338:2016· Europe

D45

Hardwood strength class: bending 45 MPa, E0,mean 13 500 MPa, ρk 580 kg/m³.

All values

Mechanical

Elastic

Modulus of elasticity parallel to grain E0,mean

ConditionValueEvidence
13 500MPaSingle source

Shear modulus Gmean

ConditionValueEvidence
840MPaSingle source

Modulus of elasticity, 5th percentile E0,05

ConditionValueEvidence
11 300MPacharacteristicSingle source

Modulus of elasticity perpendicular to grain E90,mean

ConditionValueEvidence
900MPaSingle source

Strength

Bending strength fm,k

ConditionValueEvidence
45MPacharacteristicSingle source

Tension parallel to grain ft,0,k

ConditionValueEvidence
27MPacharacteristicSingle source

Compression parallel to grain fc,0,k

ConditionValueEvidence
29MPacharacteristicSingle source

Shear strength fv,k

ConditionValueEvidence
4.4MPacharacteristicSingle source

Tension perpendicular to grain ft,90,k

ConditionValueEvidence
0.6MPacharacteristicSingle source

Compression perpendicular to grain fc,90,k

ConditionValueEvidence
5.8MPacharacteristicSingle source

Design values

Modification factor for load duration and moisture kmod

ConditionValueEvidence
0.6Single source
0.5Single source
0.7Single source
0.55Single source
0.8Single source
0.65Single source
0.9Single source
0.7Single source
1.1Single source
0.9Single source

Deformation factor (creep) kdef

ConditionValueEvidence
0.6Single source
0.8Single source
2Single source

Partial factor for the material γM

ConditionValueEvidence
1.3Single source

Physical

Characteristic density ρk

ConditionValueEvidence
580kg/m³characteristicSingle source

Mean density ρmean

ConditionValueEvidence
700kg/m³Single source

Fire

One-dimensional charring rate β0

ConditionValueEvidence
0.5mm/minSingle source

Notional charring rate βn

ConditionValueEvidence
0.55mm/minSingle source

Sources here are public pages that reproduce EN 338:2016. For design and acceptance, the standard edition named in your specification and the CE marking and Declaration of Performance of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.