EuropeEN 338:2016· Europe

D70

Hardwood strength class: bending 70 MPa, E0,mean 20 000 MPa, ρk 800 kg/m³.

All values

Mechanical

Elastic

Modulus of elasticity parallel to grain E0,mean

ConditionValueEvidence
20 000MPaSingle source

Shear modulus Gmean

ConditionValueEvidence
1 250MPaSingle source

Modulus of elasticity, 5th percentile E0,05

ConditionValueEvidence
16 800MPacharacteristicSingle source

Modulus of elasticity perpendicular to grain E90,mean

ConditionValueEvidence
1 330MPaSingle source

Strength

Bending strength fm,k

ConditionValueEvidence
70MPacharacteristicSingle source

Tension parallel to grain ft,0,k

ConditionValueEvidence
42MPacharacteristicSingle source

Compression parallel to grain fc,0,k

ConditionValueEvidence
36MPacharacteristicSingle source

Shear strength fv,k

ConditionValueEvidence
5MPacharacteristicSingle source

Tension perpendicular to grain ft,90,k

ConditionValueEvidence
0.6MPacharacteristicSingle source

Compression perpendicular to grain fc,90,k

ConditionValueEvidence
12MPacharacteristicSingle source

Design values

Modification factor for load duration and moisture kmod

ConditionValueEvidence
0.6Single source
0.5Single source
0.7Single source
0.55Single source
0.8Single source
0.65Single source
0.9Single source
0.7Single source
1.1Single source
0.9Single source

Deformation factor (creep) kdef

ConditionValueEvidence
0.6Single source
0.8Single source
2Single source

Partial factor for the material γM

ConditionValueEvidence
1.3Single source

Physical

Characteristic density ρk

ConditionValueEvidence
800kg/m³characteristicSingle source

Mean density ρmean

ConditionValueEvidence
960kg/m³Single source

Fire

One-dimensional charring rate β0

ConditionValueEvidence
0.5mm/minSingle source

Notional charring rate βn

ConditionValueEvidence
0.55mm/minSingle source

Sources here are public pages that reproduce EN 338:2016. For design and acceptance, the standard edition named in your specification and the CE marking and Declaration of Performance of the delivered product take precedence. Design factors are recommended values; your National Annex may set others.