Compare / C70/85 vs C55/67

C70/85 vs C55/67

Europe EN 1992-1-1:2004 · Concrete

C70/85

70 MPa cylinder, 85 MPa cube characteristic strength at 28 days; Ecm 41 GPa.

Europe EN 1992-1-1:2004 · Concrete

C55/67

55 MPa cylinder, 67 MPa cube characteristic strength at 28 days; Ecm 38 GPa.

Mechanical

PropertyConditionC70/85C55/67Difference
Secant modulus of elasticity Ecm28 days41 000MPa238 000MPa2−7.3 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days70MPa355MPa3−21 %
Characteristic cube strength fck,cube28 days85MPa367MPa3−21 %
Mean compressive strength fcm28 days78MPa363MPa3−19 %
Mean axial tensile strength fctm28 days4.6MPa24.2MPa2−8.7 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.2MPa23MPa2−6.3 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days6MPa25.5MPa2−8.3 %
Strain at peak stress εc1—2.7‰22.5‰2−7.4 %
Ultimate strain (analysis curve) εcu1—2.8‰23.2‰2+14 %
Strain at maximum stress (parabola-rectangle) εc2—2.4‰22.2‰2−8.3 %
Ultimate strain (parabola-rectangle) εcu2—2.7‰23.1‰2+15 %
Exponent of the parabola n—1.4521.752+21 %
Strain at maximum stress (bilinear) εc3—2‰21.8‰2−10.0 %
Ultimate strain (bilinear) εcu3—2.7‰23.1‰2+15 %

Design values

PropertyConditionC70/85C55/67Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC70/85C55/67Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC70/85C55/67Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C55/67 relative to C70/85; for ranges the lower bound is compared.