C70/85

70 MPa cylinder, 85 MPa cube characteristic strength at 28 days; Ecm 41 GPa.

High-strength concrete: the strain limits εcu fall with strength, so the section is less ductile; Eurocode 2 adds rules above C50/60.

All values

Mechanical

Elastic

Secant modulus of elasticity Ecm

ConditionValueEvidence
41 000MPaCorroborated

Poisson's ratio ν

ConditionValueEvidence
0.2Single source

Strength

Characteristic cylinder strength fck

ConditionValueEvidence
70MPacharacteristicConfirmed

Characteristic cube strength fck,cube

ConditionValueEvidence
85MPacharacteristicConfirmed

Mean compressive strength fcm

ConditionValueEvidence
78MPaConfirmed

Mean axial tensile strength fctm

ConditionValueEvidence
4.6MPaCorroborated

Characteristic tensile strength (5 % fractile) fctk,0.05

ConditionValueEvidence
3.2MPacharacteristicCorroborated

Characteristic tensile strength (95 % fractile) fctk,0.95

ConditionValueEvidence
6MPacharacteristicCorroborated

Ductility

Strain at peak stress εc1

ConditionValueEvidence
2.7‰Corroborated

Ultimate strain (analysis curve) εcu1

ConditionValueEvidence
2.8‰Corroborated

Strain at maximum stress (parabola-rectangle) εc2

ConditionValueEvidence
2.4‰Corroborated

Ultimate strain (parabola-rectangle) εcu2

ConditionValueEvidence
2.7‰Corroborated

Exponent of the parabola n

ConditionValueEvidence
1.45Corroborated

Strain at maximum stress (bilinear) εc3

ConditionValueEvidence
2‰Corroborated

Ultimate strain (bilinear) εcu3

ConditionValueEvidence
2.7‰Corroborated

Design values

Long-term coefficient on compressive strength αcc

ConditionValueEvidence
1Single source

Partial factor for the material γc

ConditionValueEvidence
1.5Single source

Physical

Unit weight γ

ConditionValueEvidence
25kN/m³Single source

Thermal

Coefficient of thermal expansion α

ConditionValueEvidence
10×10⁻⁶ /KSingle source