Compare / C70/85 vs C60/75

C70/85 vs C60/75

Europe EN 1992-1-1:2004 · Concrete

C70/85

70 MPa cylinder, 85 MPa cube characteristic strength at 28 days; Ecm 41 GPa.

Europe EN 1992-1-1:2004 · Concrete

C60/75

60 MPa cylinder, 75 MPa cube characteristic strength at 28 days; Ecm 39 GPa.

Mechanical

PropertyConditionC70/85C60/75Difference
Secant modulus of elasticity Ecm28 days41 000MPa239 000MPa2−4.9 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days70MPa360MPa3−14 %
Characteristic cube strength fck,cube28 days85MPa375MPa3−12 %
Mean compressive strength fcm28 days78MPa368MPa3−13 %
Mean axial tensile strength fctm28 days4.6MPa24.4MPa2−4.3 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.2MPa23.1MPa2−3.1 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days6MPa25.7MPa2−5.0 %
Strain at peak stress εc1—2.7‰22.6‰2−3.7 %
Ultimate strain (analysis curve) εcu1—2.8‰23‰2+7.1 %
Strain at maximum stress (parabola-rectangle) εc2—2.4‰22.3‰2−4.2 %
Ultimate strain (parabola-rectangle) εcu2—2.7‰22.9‰2+7.4 %
Exponent of the parabola n—1.4521.62+10 %
Strain at maximum stress (bilinear) εc3—2‰21.9‰2−5.0 %
Ultimate strain (bilinear) εcu3—2.7‰22.9‰2+7.4 %

Design values

PropertyConditionC70/85C60/75Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC70/85C60/75Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC70/85C60/75Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C60/75 relative to C70/85; for ranges the lower bound is compared.