Compare / C60/75 vs C70/85

C60/75 vs C70/85

Europe EN 1992-1-1:2004 · Concrete

C60/75

60 MPa cylinder, 75 MPa cube characteristic strength at 28 days; Ecm 39 GPa.

Europe EN 1992-1-1:2004 · Concrete

C70/85

70 MPa cylinder, 85 MPa cube characteristic strength at 28 days; Ecm 41 GPa.

Mechanical

PropertyConditionC60/75C70/85Difference
Secant modulus of elasticity Ecm28 days39 000MPa241 000MPa2+5.1 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days60MPa370MPa3+17 %
Characteristic cube strength fck,cube28 days75MPa385MPa3+13 %
Mean compressive strength fcm28 days68MPa378MPa3+15 %
Mean axial tensile strength fctm28 days4.4MPa24.6MPa2+4.5 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.1MPa23.2MPa2+3.2 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days5.7MPa26MPa2+5.3 %
Strain at peak stress εc1—2.6‰22.7‰2+3.8 %
Ultimate strain (analysis curve) εcu1—3‰22.8‰2−6.7 %
Strain at maximum stress (parabola-rectangle) εc2—2.3‰22.4‰2+4.3 %
Ultimate strain (parabola-rectangle) εcu2—2.9‰22.7‰2−6.9 %
Exponent of the parabola n—1.621.452−9.4 %
Strain at maximum stress (bilinear) εc3—1.9‰22‰2+5.3 %
Ultimate strain (bilinear) εcu3—2.9‰22.7‰2−6.9 %

Design values

PropertyConditionC60/75C70/85Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC60/75C70/85Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC60/75C70/85Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C70/85 relative to C60/75; for ranges the lower bound is compared.