Compare / C90/105 vs C55/67

C90/105 vs C55/67

Europe EN 1992-1-1:2004 · Concrete

C90/105

90 MPa cylinder, 105 MPa cube characteristic strength at 28 days; Ecm 44 GPa.

Europe EN 1992-1-1:2004 · Concrete

C55/67

55 MPa cylinder, 67 MPa cube characteristic strength at 28 days; Ecm 38 GPa.

Mechanical

PropertyConditionC90/105C55/67Difference
Secant modulus of elasticity Ecm28 days44 000MPa238 000MPa2−14 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days90MPa355MPa3−39 %
Characteristic cube strength fck,cube28 days105MPa367MPa3−36 %
Mean compressive strength fcm28 days98MPa363MPa3−36 %
Mean axial tensile strength fctm28 days5MPa24.2MPa2−16 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.5MPa23MPa2−14 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days6.6MPa25.5MPa2−17 %
Strain at peak stress εc1—2.8‰22.5‰2−11 %
Ultimate strain (analysis curve) εcu1—2.8‰23.2‰2+14 %
Strain at maximum stress (parabola-rectangle) εc2—2.6‰22.2‰2−15 %
Ultimate strain (parabola-rectangle) εcu2—2.6‰23.1‰2+19 %
Exponent of the parabola n—1.421.752+25 %
Strain at maximum stress (bilinear) εc3—2.3‰21.8‰2−22 %
Ultimate strain (bilinear) εcu3—2.6‰23.1‰2+19 %

Design values

PropertyConditionC90/105C55/67Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC90/105C55/67Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC90/105C55/67Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C55/67 relative to C90/105; for ranges the lower bound is compared.