Matipedia
InternationalISO 898-1· International

Property class 10.9

High-strength structural bolt for preloaded joints: 1000 MPa tensile, 900 MPa yield (nominal).

All values

Strength

Yield strength ReH

ConditionValueEvidence
≥ 940MPaSingle source

Tensile strength Rm

ConditionValueEvidence
≥ 1 040MPaSingle source

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 9%Corroborated

Design values (Eurocode)

Design yield strength fy

ConditionValueEvidence
900MPaSingle source

Design ultimate strength fu

ConditionValueEvidence
1 000MPaSingle source

Property class 10.9 in other standards

Full comparison

“Equivalent” tables online usually match grades by name. This one compares the values each standard actually guarantees, so a 30 MPa gap in yield is visible before it is in your calculation.

GradeStandardMin. yield at 10 mmTensile at 10 mmMatchWhat differs
Property class 10.9InternationalISO 898-1≥ 940MPa1≥ 1 040MPa1—Reference grade.
F3125 Grade A490United StatesASTM F3125/F3125M≥ 896MPa21 034–1 193MPa2Close match150–173 ksi (1034–1193 MPa) tensile, 130 ksi (896 MPa) yield; inch threads.

Sources here are public pages that reproduce ISO 898-1. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence.