S350GD
The most used steel for cold-formed purlins, light-gauge framing and decking: 350 MPa yield, 420 MPa tensile.
Hot-dip coated sheet and strip (zinc +Z, zinc-iron +ZF, zinc-magnesium +ZM, aluminium-zinc +AZ) for cold-formed members. “GD” means structural steel for coating; the coating designation and mass (e.g. +Z275) follow the grade. Mechanical values apply to the base steel, tested across the rolling direction.
All values
Strength
Yield strength ReH
Upper yield strength guaranteed by the product standard (minimum).
| Condition | Value | Evidence |
|---|---|---|
| ≥ 350MPa | Corroborated |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 420MPa | Corroborated |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 16% | Corroborated |
Design values (Eurocode)
Design yield strength fy
Nominal value used in design calculations (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 350MPa | Single source |
Design ultimate strength fu
Nominal ultimate strength used in design calculations.
| Condition | Value | Evidence |
|---|---|---|
| 420MPa | Single source |
Chemical composition
Show on the periodic tableS350GD, heat analysis, % by mass, maximum
| Element | Applies to | Max % | Evidence |
|---|---|---|---|
| C | all thicknesses | 0.20 | Single source |
| Si | all thicknesses | 0.60 | Single source |
| Mn | all thicknesses | 1.70 | Single source |
| P | all thicknesses | 0.10 | Single source |
| S | all thicknesses | 0.045 | Single source |
S350GD in other standards
Full comparison“Equivalent” tables online usually match grades by name. This one compares the values each standard actually guarantees, so a 30 MPa gap in yield is visible before it is in your calculation.
| Grade | Standard | Min. yield at 10 mm | Tensile at 10 mm | Match | What differs |
|---|---|---|---|---|---|
| S350GD | ≥ 350MPa2 | ≥ 420MPa2 | — | Reference grade. | |
| A653 SS Grade 50 Class 1 | ≥ 340MPa2 | ≥ 450MPa1 | Approximate | Yield 340 MPa (50 ksi), 10 MPa lower; tensile 450 MPa (Class 1), higher. Elongation 12 % on 2 in., not comparable with A80. | |
| SGC490 | ≥ 365MPa1 | ≥ 490MPa1 | Approximate | Higher guaranteed yield (365 MPa) and tensile (490 MPa); listed as the JIS counterpart. |
Sources here are public pages that reproduce EN 10346:2015. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence.