Europe EN 1992-1-1:2004 · Concrete

C55/67

55 MPa cylinder, 67 MPa cube characteristic strength at 28 days; Ecm 38 GPa.

Europe EN 1992-1-1:2004 · Concrete

C60/75

60 MPa cylinder, 75 MPa cube characteristic strength at 28 days; Ecm 39 GPa.

Mechanical

PropertyConditionC55/67C60/75Difference
Secant modulus of elasticity Ecm28 days38 000MPa239 000MPa2+2.6 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days55MPa360MPa3+9.1 %
Characteristic cube strength fck,cube28 days67MPa375MPa3+12 %
Mean compressive strength fcm28 days63MPa368MPa3+7.9 %
Mean axial tensile strength fctm28 days4.2MPa24.4MPa2+4.8 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3MPa23.1MPa2+3.3 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days5.5MPa25.7MPa2+3.6 %
Strain at peak stress εc1—2.5‰22.6‰2+4.0 %
Ultimate strain (analysis curve) εcu1—3.2‰23‰2−6.3 %
Strain at maximum stress (parabola-rectangle) εc2—2.2‰22.3‰2+4.5 %
Ultimate strain (parabola-rectangle) εcu2—3.1‰22.9‰2−6.5 %
Exponent of the parabola n—1.7521.62−8.6 %
Strain at maximum stress (bilinear) εc3—1.8‰21.9‰2+5.6 %
Ultimate strain (bilinear) εcu3—3.1‰22.9‰2−6.5 %

Design values

PropertyConditionC55/67C60/75Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC55/67C60/75Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC55/67C60/75Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C60/75 relative to C55/67; for ranges the lower bound is compared.