Matipedia

Compare / C60/75 vs C55/67

C60/75 vs C55/67

Europe EN 1992-1-1:2004 · Concrete

C60/75

60 MPa cylinder, 75 MPa cube characteristic strength at 28 days; Ecm 39 GPa.

Europe EN 1992-1-1:2004 · Concrete

C55/67

55 MPa cylinder, 67 MPa cube characteristic strength at 28 days; Ecm 38 GPa.

Mechanical

PropertyConditionC60/75C55/67Difference
Secant modulus of elasticity Ecm28 days39 000MPa238 000MPa2−2.6 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days60MPa355MPa3−8.3 %
Characteristic cube strength fck,cube28 days75MPa367MPa3−11 %
Mean compressive strength fcm28 days68MPa363MPa3−7.4 %
Mean axial tensile strength fctm28 days4.4MPa24.2MPa2−4.5 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.1MPa23MPa2−3.2 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days5.7MPa25.5MPa2−3.5 %
Strain at peak stress εc1—2.6‰22.5‰2−3.8 %
Ultimate strain (analysis curve) εcu1—3‰23.2‰2+6.7 %
Strain at maximum stress (parabola-rectangle) εc2—2.3‰22.2‰2−4.3 %
Ultimate strain (parabola-rectangle) εcu2—2.9‰23.1‰2+6.9 %
Exponent of the parabola n—1.621.752+9.4 %
Strain at maximum stress (bilinear) εc3—1.9‰21.8‰2−5.3 %
Ultimate strain (bilinear) εcu3—2.9‰23.1‰2+6.9 %

Design values

PropertyConditionC60/75C55/67Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC60/75C55/67Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC60/75C55/67Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C55/67 relative to C60/75; for ranges the lower bound is compared.