Compare / C60/75 vs C80/95

C60/75 vs C80/95

Europe EN 1992-1-1:2004 · Concrete

C60/75

60 MPa cylinder, 75 MPa cube characteristic strength at 28 days; Ecm 39 GPa.

Europe EN 1992-1-1:2004 · Concrete

C80/95

80 MPa cylinder, 95 MPa cube characteristic strength at 28 days; Ecm 42 GPa.

Mechanical

PropertyConditionC60/75C80/95Difference
Secant modulus of elasticity Ecm28 days39 000MPa242 000MPa2+7.7 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days60MPa380MPa3+33 %
Characteristic cube strength fck,cube28 days75MPa395MPa3+27 %
Mean compressive strength fcm28 days68MPa388MPa3+29 %
Mean axial tensile strength fctm28 days4.4MPa24.8MPa2+9.1 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.1MPa23.4MPa2+9.7 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days5.7MPa26.3MPa2+11 %
Strain at peak stress εc1—2.6‰22.8‰2+7.7 %
Ultimate strain (analysis curve) εcu1—3‰22.8‰2−6.7 %
Strain at maximum stress (parabola-rectangle) εc2—2.3‰22.5‰2+8.7 %
Ultimate strain (parabola-rectangle) εcu2—2.9‰22.6‰2−10 %
Exponent of the parabola n—1.621.42−13 %
Strain at maximum stress (bilinear) εc3—1.9‰22.2‰2+16 %
Ultimate strain (bilinear) εcu3—2.9‰22.6‰2−10 %

Design values

PropertyConditionC60/75C80/95Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC60/75C80/95Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC60/75C80/95Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C80/95 relative to C60/75; for ranges the lower bound is compared.