Compare / C80/95 vs C70/85

C80/95 vs C70/85

Europe EN 1992-1-1:2004 · Concrete

C80/95

80 MPa cylinder, 95 MPa cube characteristic strength at 28 days; Ecm 42 GPa.

Europe EN 1992-1-1:2004 · Concrete

C70/85

70 MPa cylinder, 85 MPa cube characteristic strength at 28 days; Ecm 41 GPa.

Mechanical

PropertyConditionC80/95C70/85Difference
Secant modulus of elasticity Ecm28 days42 000MPa241 000MPa2−2.4 %
Poisson's ratio νuncracked0.210.21same
Characteristic cylinder strength fck28 days80MPa370MPa3−13 %
Characteristic cube strength fck,cube28 days95MPa385MPa3−11 %
Mean compressive strength fcm28 days88MPa378MPa3−11 %
Mean axial tensile strength fctm28 days4.8MPa24.6MPa2−4.2 %
Characteristic tensile strength (5 % fractile) fctk,0.0528 days3.4MPa23.2MPa2−5.9 %
Characteristic tensile strength (95 % fractile) fctk,0.9528 days6.3MPa26MPa2−4.8 %
Strain at peak stress εc1—2.8‰22.7‰2−3.6 %
Ultimate strain (analysis curve) εcu1—2.8‰22.8‰2same
Strain at maximum stress (parabola-rectangle) εc2—2.5‰22.4‰2−4.0 %
Ultimate strain (parabola-rectangle) εcu2—2.6‰22.7‰2+3.8 %
Exponent of the parabola n—1.421.452+3.6 %
Strain at maximum stress (bilinear) εc3—2.2‰22‰2−9.1 %
Ultimate strain (bilinear) εcu3—2.6‰22.7‰2+3.8 %

Design values

PropertyConditionC80/95C70/85Difference
Long-term coefficient on compressive strength αcc—1111same
Partial factor for the material γcpersistent and transient design situations1.511.51same

Physical

PropertyConditionC80/95C70/85Difference
Unit weight γreinforced, normal percentage of reinforcement25kN/m³125kN/m³1same

Thermal

PropertyConditionC80/95C70/85Difference
Coefficient of thermal expansion α—10×10⁻⁶ /K110×10⁻⁶ /K1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are C70/85 relative to C80/95; for ranges the lower bound is compared.