Matipedia

Compare / 350W vs S355

350W vs S355

Canada CSA G40.21 · Steel

350W

Canada's standard weldable structural grade: 350 MPa (50 ksi) yield, 450–650 MPa tensile.

Europe EN 10025-2:2019 · Steel

S355

Europe's workhorse structural steel: 355 MPa minimum yield up to 16 mm, 470–630 MPa tensile from 3 to 100 mm.

ApproximateYield 350 MPa (50 ksi), 5 MPa below S355, and only 46 ksi above 2½ in.; tensile 65–95 ksi. W has no guaranteed impact test; 350WT adds it.

Mechanical

PropertyCondition350WS355Difference
Yield strength ReHt = 16 mm≥ 350MPa1≥ 355MPa3+1.4 %
t = 40 mm≥ 350MPa1≥ 345MPa3−1.4 %
t = 63 mm≥ 350MPa1≥ 335MPa2−4.3 %
t = 63.5 mm≥ 350MPa1≥ 325MPa3−7.1 %
t = 80 mm≥ 317MPa1≥ 325MPa3+2.5 %
t = 100 mm≥ 317MPa1≥ 315MPa3−0.6 %
t = 101.6 mm≥ 317MPa1≥ 295MPa2−6.9 %
Tensile strength Rmt = 3 mm450–655MPa2510–680MPa3+13 %
t = 100 mm450–655MPa2470–630MPa5+4.4 %
t = 150 mm450–655MPa2450–600MPa2same
t = 250 mm450–655MPa2450–600MPa1same
t = 400 mm450–655MPa2450–600MPa1same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are S355 relative to 350W; for ranges the lower bound is compared.