Matipedia

Compare / S355 vs 350W

S355 vs 350W

Europe EN 10025-2:2019 · Steel

S355

Europe's workhorse structural steel: 355 MPa minimum yield up to 16 mm, 470–630 MPa tensile from 3 to 100 mm.

Canada CSA G40.21 · Steel

350W

Canada's standard weldable structural grade: 350 MPa (50 ksi) yield, 450–650 MPa tensile.

ApproximateYield 350 MPa (50 ksi), 5 MPa below S355, and only 46 ksi above 2½ in.; tensile 65–95 ksi. W has no guaranteed impact test; 350WT adds it.

Mechanical

PropertyConditionS355350WDifference
Yield strength ReHt = 16 mm≥ 355MPa3≥ 350MPa1−1.4 %
t = 40 mm≥ 345MPa3≥ 350MPa1+1.4 %
t = 63 mm≥ 335MPa2≥ 350MPa1+4.5 %
t = 63.5 mm≥ 325MPa3≥ 350MPa1+7.7 %
t = 80 mm≥ 325MPa3≥ 317MPa1−2.5 %
t = 100 mm≥ 315MPa3≥ 317MPa1+0.6 %
t = 101.6 mm≥ 295MPa2≥ 317MPa1+7.5 %
Tensile strength Rmt = 3 mm510–680MPa3450–655MPa2−12 %
t = 100 mm470–630MPa5450–655MPa2−4.3 %
t = 150 mm450–600MPa2450–655MPa2same
t = 250 mm450–600MPa1450–655MPa2same
t = 400 mm450–600MPa1450–655MPa2same

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are 350W relative to S355; for ranges the lower bound is compared.