S355J2H
Cold-formed welded hollow sections (SHS, RHS, CHS): 355 MPa yield, 470–630 MPa tensile, 27 J at −20 °C.
- Tensile strength Rm
- 470–630MPaConfirmed3–40 mm
- Elongation after fracture A
- ≥ 20%Corroborated
- Design yield strength fy
- 355MPaSingle source≤ 40 mm
- Design ultimate strength fu
- 510MPaSingle source≤ 40 mm
All values
Strength
Yield strength ReH
Upper yield strength guaranteed by the product standard (minimum).
| Condition | Value | Evidence |
|---|---|---|
| ≥ 355MPa | Corroborated |
Tensile strength Rm
Ultimate tensile strength. Product standards give a range or a minimum.
| Condition | Value | Evidence |
|---|---|---|
| 510–680MPa | Corroborated | |
| 470–630MPa | Confirmed |
Ductility
Elongation after fracture A
Minimum elongation; depends on gauge length and test direction.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 20% | Corroborated |
Toughness
Impact energy (Charpy V) KV
Minimum absorbed energy at the stated test temperature.
| Condition | Value | Evidence |
|---|---|---|
| ≥ 27J | Corroborated |
Design values (Eurocode)
Design yield strength fy
Nominal value used in design calculations (before partial factors).
| Condition | Value | Evidence |
|---|---|---|
| 355MPa | Single source |
Design ultimate strength fu
Nominal ultimate strength used in design calculations.
| Condition | Value | Evidence |
|---|---|---|
| 510MPa | Single source |
S355J2H in other standards
Full comparison“Equivalent” tables online usually match grades by name. This one compares the values each standard actually guarantees, so a 30 MPa gap in yield is visible before it is in your calculation.
| Grade | Standard | Min. yield at 10 mm | Tensile at 10 mm | Match | What differs |
|---|---|---|---|---|---|
| S355J2H | ≥ 355MPa2 | 470–630MPa3 | — | Reference grade. | |
| A500 Grade C | ≥ 345MPa2 | ≥ 425MPa2 | Approximate | Shaped A500 Grade C guarantees 345 MPa (50 ksi) and only 425 MPa tensile; round tubes only 315 MPa (46 ksi). No impact test. | |
| A1085 | 345–483MPa1 | ≥ 450MPa1 | Approximate | 345 MPa (50 ksi) yield with a 70 ksi cap, 450 MPa tensile, tighter wall tolerance; designed for seismic and full-thickness design. |
Not yet verified for this grade
- Yield above 16 mm
- EN 10210 hot-finished values
Missing on purpose: a value appears here only once a public source states it.
Sources here are public pages that reproduce EN 10219-1. For design and acceptance, the standard edition named in your specification and the inspection certificate (EN 10204 3.1) of the delivered product take precedence.