Matipedia

Compare / S355J2H (EN 10210, hot finished) vs S355J2H

S355J2H (EN 10210, hot finished) vs S355J2H

Europe EN 10210 · Steel

S355J2H (EN 10210, hot finished)

Hot finished hollow sections: 355 MPa yield up to 16 mm, 470–630 MPa tensile — and fu = 490 MPa in design, not the 510 MPa of cold-formed EN 10219 sections.

Europe EN 10219-1 · Steel

S355J2H

Cold-formed welded hollow sections (SHS, RHS, CHS): 355 MPa yield, 470–630 MPa tensile, 27 J at −20 °C.

Mechanical

PropertyConditionS355J2H (EN 10210, hot finished)S355J2HDifference
Yield strength ReHt = 16 mm≥ 355MPa1≥ 355MPa2same
Tensile strength Rmt = 3 mm—510–680MPa2
t = 40 mm470–630MPa1470–630MPa3same
Elongation after fracture A—≥ 22%1≥ 20%2−9.1 %

Design values

PropertyConditionS355J2H (EN 10210, hot finished)S355J2HDifference
Design yield strength fyt = 40 mm355MPa1355MPa1same
Design ultimate strength fut = 40 mm490MPa1510MPa1+4.1 %

Thermal

PropertyConditionS355J2H (EN 10210, hot finished)S355J2HDifference
Specific heat capacity cpat +20 °C440J/(kg·K)2440J/(kg·K)2same
Thermal conductivity λat +20 °C53.3W/(m·K)153.3W/(m·K)1same

Fire

PropertyConditionS355J2H (EN 10210, hot finished)S355J2HDifference
Effective yield strength reduction factor ky,θat +20 °C1111same
at +100 °C1111same
at +200 °C1111same
at +300 °C1111same
at +400 °C1111same
at +500 °C0.7810.781same
at +600 °C0.4710.471same
at +700 °C0.2310.231same
at +800 °C0.1110.111same
at +900 °C0.0610.061same
at +1000 °C0.0410.041same
at +1100 °C0.0210.021same
at +1200 °C0101
Proportional limit reduction factor kp,θat +20 °C1111same
at +100 °C1111same
at +200 °C0.80710.8071same
at +300 °C0.61310.6131same
at +400 °C0.4210.421same
at +500 °C0.3610.361same
at +600 °C0.1810.181same
at +700 °C0.07510.0751same
at +800 °C0.0510.051same
at +900 °C0.037510.03751same
at +1000 °C0.02510.0251same
at +1100 °C0.012510.01251same
at +1200 °C0101
Elastic modulus reduction factor kE,θat +20 °C1111same
at +100 °C1111same
at +200 °C0.910.91same
at +300 °C0.810.81same
at +400 °C0.710.71same
at +500 °C0.610.61same
at +600 °C0.3110.311same
at +700 °C0.1310.131same
at +800 °C0.0910.091same
at +900 °C0.067510.06751same
at +1000 °C0.04510.0451same
at +1100 °C0.022510.02251same
at +1200 °C0101

Rows are matched by condition (thickness band, temperature, product form). A dash means the grade has no sourced value for that condition. Differences are S355J2H relative to S355J2H (EN 10210, hot finished); for ranges the lower bound is compared.