US quenched and tempered plate: 100 ksi (690 MPa) yield up to 2.5 in, 90 ksi above, 110–130 ksi tensile.

Each A514 grade letter is a chemistry limited to a maximum thickness; Grade Q goes to 6 in. No impact test unless ordered as a supplement.

Compared with S690QL on its equivalents table.

Yield strength ReH
≥ 690 MPa1guaranteed minimum
Tensile strength Rm
760–895 MPa1guaranteed range
Elongation after fracture A
≥ 16 %1guaranteed minimum · in 2 in.
Brinell hardness HB
235–293 HB1guaranteed range
How we know these values · 7 values from 1 source
Single source
7
  • Click any value under “All values” to see the sources that state it, with dates.
  • How we rate evidence

What to watch

  • Guaranteed yield strength depends on thickness: 690 MPa for 4.7–63.5 mm, down to 620 MPa for 63.5–152 mm.
  • As a substitute for S690QL: Same 690 MPa (100 ksi) minimum up to 2.5 in, but A514 has no standard impact test and its 90 ksi step comes at 63.5 mm, not 50 mm.

All values

  • Identity and composition not yet
  • Mechanical 7
  • Design values not yet
  • Physical not yet
  • Thermal not yet
  • Fire not yet
  • Chemical and durability not yet

Mechanical

Strength

Yield strength ReH

ConditionValueEvidence
≥ 690MPaSingle source
≥ 620MPaSingle source

Tensile strength Rm

ConditionValueEvidence
760–895MPaSingle source
690–895MPaSingle source

Brinell hardness HB

ConditionValueEvidence
235–293HBSingle source

Ductility

Elongation after fracture A

ConditionValueEvidence
≥ 16%Single source
≥ 14%Single source

Listed as equivalent to

  • S690QL (EN 10025-6) — Same 690 MPa (100 ksi) minimum up to 2.5 in, but A514 has no standard impact test and its 90 ksi step comes at 63.5 mm, not 50 mm.

Compare side by side